12 - 11 TROUBLESHOOTING AND ROUTINE MAINTENANCE
Routine maintenance
Cleaning the scanner
1
Unplug the power cord for safety.
2
Open the top cover by lifting the lever on the right side of the top
cover.
3
Clean the white bar and the glass strip under the bar with
isopropyl alcohol on a lint-free cloth. Be careful not to bend the
spring plate or drop anything into your fax machine.
4
Close the top cover.
Press down on both sides of the top cover until it clicks.
White Bar
Glass Strip