Brother FAX-8650P All in One Printer User Manual


 
V - 45
WSW34 (Function setting 12)
Selector
No.
Function Setting and Specifications
1
|
5
Not used.
6
7
Number of DTMF tone signals for
inhibiting the detection of CNG
during external TAD operation
No. 6 7
0 0 : 3
0 1 : 2
1 0 : 1
1 1 : OFF
8
CNG detection when the external
telephone is connected with a line
TAD mode
0: Only when the 1: Always
equipment detects
itself being called
l Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external
TAD operation
If the equipment receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
l Selector 8: CNG detection when the external telephone is connected with a line in TAD
If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being
called. If the external telephone is connected with a line before the equipment detects itself being
called, the equipment will not longer detect a CNG signal.
If this selector is set to"1," the equipment will detect a CNG signal every time the external
telephone is connected with a line, even without detecting itself being called.
WSW35 (Function setting 13)
Selector
No.
Function Setting and Specifications
1
|
8
Not used.