code
Message Meaning Solution
6110
Fail: BY EEP WRT
Failure in writing to EEPROM of
BY
**
6111
Fail: BY FLSH ERS
Failure in clearing FLASH ROM of
BY
6112
Fail: BY FLSH WRT
Failure in writing to FLASH ROM of
BY
6113
Fail: BY FLSH CHK
Defect in FLASH ROM Check
Sum of BY
**
6114
Fail: BY RAM Test Defect in RAM check of BY **
6134
Fail: Head VLTG Print Head voltage defect **
6150
Fail: Sur Temp
Ambient temperature sensor
defect
**
6200
Fail: MNT Cap Drv
The operation stopped because
the Cap Driver has overheated.
6210
Fail: MNT Pump Drv
The operation stopped because
the Pump Driver has overheated.
6220
Fail: MNT Wipe Drv
The operation stopped because
the Wipe Driver has overheated.
**
6230
Fail: MNT INK-PCBA
The Maintenance Unit failed to
communicate with the Ink Sensor A
PCB.
**
6240
Fail: MNT INK-PCBB
The Maintenance Unit failed to
communicate with the Ink Sensor
B PCB.
**
PRG: SH SCER
1508
Carriage initialization failed.
PRG: SH SCER
1757
Reading EEPROM Timeout (BY)
PRG: SH SCER
1788
Writing EEPROM Timeout (BY)
7000
PRG: SH SCER
XXXX
Communication timeout (SH to
BY)
**
7001
PRG: SH Exception
Error inside the program
(Exceptionally occurs in CPU of
SH)
**
7002
PRG: SH ILGL TMR
Error inside the program
(Incorrect timer setting of SH)
**
7010
PRG: SH ILGL Arg
Error inside the program
(Argument defect of SH)
**
7011
PRG: SH ILGL RTN
Error inside the program
(Returning value defect of SH)
7012
PRG: SH Event TO
Error inside the program
(Time-out of waiting for the
vent/message of SH)
7013
PRG: SH Internal
Error inside the program
(General program error of SH)
7100
PRG: BY SYSCALL
Error inside the program
(System call error of BY)
**