60
g Clean the corona wire inside the drum
unit by gently sliding the green tab from
left to right and right to left several times.
Note
Be sure to return the tab to the home
position (a) (1). If you do not, printed
pages may have a vertical stripe.
h Put the drum unit and toner cartridge
assembly back into the machine. Close
the front cover.
Note
After replacing the toner cartridge, DO
NOT turn off the machine’s power switch
or open the front cover until the LCD
clears the Please Wait message and
returns to Ready mode.
Cleaning the corona wire A
If you have print quality problems, clean the
corona wire as follows:
a Open the front cover, and then leave the
machine turned on for 10 minutes for the
internal fan to cool the internal parts of
the machine that are extremely hot.
WARNING
HOT SURFACE
After you have just used the machine, some
internal parts of the machine will be
extremely hot. Wait for the machine to cool
down before you touch the internal parts of
the machine.
1