Cabletron Systems 2E43-51 Switch User Manual


 
Chapter 5: Local Management
5-58 2E43-51/2E43-51R User’s Guide
5.16.2 Changing Source and Destination Ports
Add or delete source port and destination port entries as follows:
1. Use the arrow keys to highlight the Source Port field.
2. Press the SPACE bar or BACKSPACE one or more times to increment
or decrement the port number displayed in the brackets [n] until the
appropriate port number displays.
3. Use the arrow keys to highlight the Destination Port field.
4. Use the SPACE bar or BACKSPACE to step to the appropriate port
number for the destination port.
5. Use the arrow keys to highlight the Status field.
6. Use the SPACE bar to select either the ADD or DEL (delete) option.
Press ENTER. This adds or deletes the port selections made in steps 2
and 4 and also updates the screen Source Port and Destination Port list.
7. Use the arrow keys to highlight SAVE at the bottom of the screen.
Press ENTER. The message “SAVED OK” displays. This saves the
new settings and updates the Source Port and Destination Port
read-only fields.
5.17 BROADCAST SUPPRESSION SCREEN
The Broadcast Suppression screen, Figure 5-24, allows the user to set a
desired limit of receive broadcast frames that are switched out to the other
ports.
NOTE
To redirect more than one port, repeat steps 1 through 6 for
each additional setting, then go to step 7 to save all the new
settings at once.
NOTE
The Broadcast Suppression screen is not available if the
operational mode of the device is set to SECURE FAST VLAN.
This screen may only be used when the device is configured to
operate as an 802.1D or 802.1Q switch.
Broadcast frames received above the threshold setting are
dropped.