Cabletron Systems 2E43-51 Switch User Manual


 
System Resources Screen
2E43-51/2E43-51R User’s Guide 5-43
NVRAM Installed (Read-only)
Indicates the amount of NVRAM installed in the 2E43-51 and how much
of it is currently available.
Current Switch Utilization (Read-only)
Shows the percentage of the device switching capacity currently being
used.
Peak Switch Utilization (Read-only)
Shows the peak percentage of device switching capacity used, since the
last reset.
Reset Peak Switch Utilization (Toggle)
Allows the user to reset the Peak Switch Utilization field. The switch may
be set to either YES or NO as described in Section 5.12.1. YES resets the
Peak Switch Utilization field to the current system traffic.
5.12.1 Setting the Reset Peak Switch Utilization
To set the Reset Peak Switch Utilization field to YES or NO, proceed as
follows:
1. Use the arrow keys to highlight the Reset Peak Switch Utilization
field.
2. Press the SPACE bar to select YES or NO.
3. Use the arrows keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” displays.