Cabletron Systems HSIM-W87 Switch User Manual


 
Network Tools
HSIM-W87 User’s Guide 4-11
Example:
command: dsx3
Syntax: dsx3
dsx3 near
dsx3 near <1..96>
dsx3 linetype <M23|CBITPARITY> <line>
dsx3 loopback <no|payload|line> <line>
dsx3 txclksrc <loop|local> <line>
dsx3 <line>
dsx3 <line>
<PES|PSES|SEFS|UAS|LCV|PCV|LES|CCV|CES|CSES
>
Description: Allows the user to read the contents of several tables
defined in RFC 1407.
“line” refers to the number of an instance of a physical
DS3 interface. A different “line” is in the choice between
no,
payload, and line for the loopback function. The
acronyms in caps refer to error types defined in the RFC.
<1..96> is the number of a previous 15 minute
measurement interval. Interval “1” is always the latest
interval to have taken place, with interval “2” as the next
latest, etc.
-> dsx1
2689_2
DS1 1406 Configuration:
LIne Time Intvl Type Coding LoopCfg Status TxClk FDL
29 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
30 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
31 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
32 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
33 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
34 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
35 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
36 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
37 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
38 504 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
39 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
40 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
41 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
42 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
43 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
44 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
45 505 1 ESF B8ZS NoLoop OtherFailure loop Fdlnone
----More----