Cabletron Systems SSIM-H2-02 Switch User Manual


 
11
SSIM-H2-02 Fast Ethernet - Translational Switch SmartStack Interface Module Installation and User Guide Installation
Power-On Self Test
When you start the switch, it will run a power-on self-test to ensure that all the
devices are working correctly. During this test, the switch will detect and start any
module found in an expansion slot.
The module will then perform an internal power-on self test. During the entire test,
the DIAG and ERR LEDs will be lit while the other LEDs may turn on and off.
The test lasts a few minutes. If no problems are found, the DIAG and ERR LEDs
turn off and the module enters its normal operational state. If a problem is found,
the DIAG LED will turn off and the ERR LED will remain on. Messages in the
message log or on the console will indicate what the problem is.
Note:
Switch Console message:
Press RETURN key to activate console...
means that the console is available, but it takes more time to activate the module.
You can check if they are up in the
Configuration
Module Information
menu.
100 (green) Middle
On
The port is in 100 Mbps mode.
Off
The port is in 10 Mbps mode.
LINK (green) Bottom
On
The port is active.
Off
The port is disabled or not
inserted.
Table 3. LEDs at the Right of Every Port