17-23
Cisco ONS 15600 Procedure Guide, R8.0
Chapter 17 DLPs E100 to E199
DLP- E126 Provision the IIOP Listener Port on the CTC Computer
• Other Constant—If Port 683 is not used, type the IIOP port specified by your firewall administrator.
Step 3 Click Apply.
Step 4 When the Change Network Configuration message appears, click Yes.
Both Timing and Shelf controllers (TSCs) reboot, one at a time. The reboot will take approximately
15 minutes.
Step 5 Return to your originating procedure (NTP).
DLP-E126 Provision the IIOP Listener Port on the CTC Computer
Step 1 From the Edit menu, choose Preferences.
Step 2 In the Preferences dialog box, click the Firewall tab.
Step 3 In the CTC CORBA (IIOP) Listener Port area, choose a listener port option:
• Default - Variable—Use to connect to ONS 15600s from within a firewall or if no firewall is used
(default).
• Standard Constant—Use Port 683, the CORBA default port number.
• Other Constant—If Port 683 is not used, enter the IIOP port defined by your administrator.
Step 4 Click Apply. A warning appears telling you that the port change will apply during the next CTC login.
Step 5 Click OK.
Step 6 In the Preferences dialog box, click OK.
Step 7 To access the ONS 15600 using the IIOP port, log out of CTC then log back in. (To log out, choose Exit
from the File menu.)
Step 8 Return to your originating procedure (NTP).
Purpose This task selects the IIOP listener port on CTC.
Tools/Equipment IIOP listener port number from LAN or firewall administrator
Prerequisite Procedures NTP-E21 Verify Card Installation, page 4-2
DLP-E26 Log into CTC, page 16-33
Required/As Needed Required only if the computer running CTC resides behind a firewall
Onsite/Remote Onsite or remote
Security Level Provisioning or higher