Citizen Systems CBM-253 Printer User Manual


 
CBM-253 User’s Manual
89
CITIZEN
GS C I n1 n2 n3 n4 n5 n6
[Name] Setting of the numbering counting mode (A)
[Code] <1D>H <43>H <31>H <n1> <n2> <n3> <n4> <n5> <n6>
[Defined ranges] 0 n1 255
0 n2 255
0 n3 255
0 n4 255
0 n5 255
0 n6 255
[Function] Sets the numbering mode (consecutive numbering counter).
Initial value of the counter = n1 + n2 x 256 (n1 is the remainder and n2 is the quotient)
Final value of the counter = n3 + n4 x 256 (n3 is the remainder and n4 is the quotient)
When counting up:
When n1 + n2 × 256 < n3 + n4 × 256 and n50 and n60, counting up will be carried
out.
n1 + n2 × 256 will be the minimum value of the counter, and n3 + n4 × 256 will be the
maximum value of the counter.
When counting down:
When n1 + n2 x 256 > n3 + n4 × 256 and n50 and n60. counting down will be carried
out.
n1 + n2 × 256 will be the maximum value of the counter. and n3 + n4 × 256 will be the
minimum value of the counter.
To stop the counter:
When n1 + n2 × 256 = n3 + n4 × 256 or n5 = 0 or n6 = 0, the counting will stop.
n5 indicates the step amount during the counting up or counting down.
n6 indicates the number of repetitions while the counter remains fixed.