GS C ; N1 ; N2 ; N3 ; N4 ; N5 ;
[Name] Setting of the numbering counting mode (B)
[Code] <1D>H <43>H <3B>H <N1> <3B>H <N2> <3B>H <N3>
<3B>H <N4> <3B>H <N5> <3B>H
* <N1> ~ <N5> are received BY character code.
[Defined ranges] 0 ≤ N1 ≤ 65535
0 ≤ N2 ≤ 65535
0 ≤ N3 ≤ 255
0 ≤ N4 ≤ 255
0 ≤ N5 ≤ 65535
[Function] Sets the numbering mode (consecutive numbering counter), and sets the counter value.
When counting up:
• When N1 < N2 and N3≠0 and N4≠0, counting up will be carried out.
• N1 will be the minimum value of the counter, and N2 will be the maximum value of the
counter.
When counting down:
• When N1 > N2 and N3≠0 and N4≠0. counting down will bc carried out.
• N1 will be the maximum value of the counter, and N2 will be the minimum value of the
counter.
To stop the counter:
• When N1 = N2 or N3 = 0 or N4 = 0, the counting will stop.
• N3 indicates the step amount during the counting up or counting down.
• N4 indicates the number of repetition while the counter remains fixed.
• N5 indicates the counter value.