Maintenance and Service Guide 5-21
Addendum 108431-001 (11-88) to
Manual No. 108033-003
Table 5-2. Advanced Diagnostics Error Codes Continued
Error
Code
Description
Recommended
Action
1206-xx Dial Multifrequency Tone Test. The following steps apply to error codes 1201-xx
through 1210-xx:
1. Refer to the modem documentation for correct setup
procedures.
2. Check the modem, line.
3. Replace the modem and retest.
17 Tone detection failure.
1210-xx Modem Direct Connect Test.
01 Modem timed out waiting for SYNC.
02 Modem timed out waiting
for response.
03 Modem exceeded data block
retry limit.
04 RCV exceeded carrier lost limit.
05 XMIT exceeded carrier lost limit.
06 Time-out waiting for dial tone.
07 Dial number string too long.
08 Modem timed out waiting for
remote response.
09 Modem exceeded maximum
redial limit.
10 Line quality prevented remote
connection.
11 Modem timed out waiting for
remote connection.
Continued...