Compaq 386 Personal Computer User Manual


 
Maintenance and Service Guide 5-7
Addendum 108431-001 (11-88) to
Manual No. 108033-003
Table 5-2. Advanced Diagnostics Error Codes Continued
Error
Code Description
Recommended
Action
105-07 Port 61 bit 3 not at one. Replace the system board and retest for error codes
103-xx through 113-xx.
105-08 Port 61 bit 1 not at one.
105-09 Port 61 bit 0 not at one.
105-10 Port 61 I/O test failed.
105-11 Port 61 bit 7 not at zero.
105-12 Port 61 bit 2 not at zero.
105-13 No interrupt generated by
failsafe timer.
105-14 NMI not triggered by failsafe timer.
106-01 Keyboard controller self-test failed.
107-01 CMOS RAM test failed.
108-02 CMOS interrupt test failed.
108-03 CMOS interrupt test, CMOS not
properly initialized.
109-01 CMOS clock load data test failed.
109-02 CMOS clock rollover test failed.
109-03 CMOS clock test, CMOS not
properly initialized.
110-01 Programmable timer load data
test failed.
110-02 Programmable timer dynamic
test failed.
110-03 Programmable timer #2 load data
test failed.
Continued...