Wand Signal Speed
Product Reference Guide 103
Wand Signal Speed
This feature specifies the speed of the Wand output signal per nominal bar or space. Choices
are:
• 330 microseconds
• 660 microseconds
NOTE
ENTER/EXIT PROGRAMMING MODE
Wand Signal Speed = 330ms
Wand Signal Speed = 660ms
TTL logic levels:
0
V <= Low <= 0.7V
2.4V <= High <= 5.25V
DEFAULT