Datalogic Scanning I GD4100 Barcode Reader User Manual


 
RS-232 ONLY Interface
56 Gryphon™ I GD4100
Parity
This feature specifies parity required for sending and receiving data. A parity check bit is the
most significant bit of each ASCII coded character. Select the parity type according to host
device requirements.
Select None when no parity bit is required.
Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an
odd number of 1 bits are contained in the coded character.
Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an
ev
en number of 1 bits are contained in the coded character.
ENTER/EXIT PROGRAMMING MODE
Parity = None
Parity = Even
Parity = Odd
DEFAULT