Introduction 25
RACADM Command Options
Table 1-1 lists the options for the RACADM command.
Table 1-2 provides the supported RACADM interfaces for iDRAC6
Enterprise and iDRAC6 Express.
Table 1-1. RACADM Command Options
Option Description
-r <racIpAddr>
-r <racIpAddr>:<port
number>
Specifies the controller’s remote IP address.
Use:<port number> if the iDRAC6 port number is not
the default port (443)
-u <usrName> Specifies the user name that is used to authenticate
the command transaction. If the -u option is used, the
-p option must be used, and the -i option (interactive)
is not allowed.
-p <password> Specifies the password used to authenticate the
command transaction. If the -p option is used, the -i
option is not allowed.
-S Specifies that RACADM should check for invalid
certificate errors. RACADM stops the execution of the
command with an error message if it detects an invalid
certificate.
-i <indexnumber> Specifies the index number for the indexed group, if
applicable.
-g <groupname> Specifies the group name if applicable.
-o <objectname> Specifies the object name if applicable.
Table 1-2. Supported RACADM Interfaces
iDRAC Type Local RACADM SSH/Telnet RACADM Remote RACADM
iDRAC6 Enterprise
iDRAC6 Express
CMC
= Supported; = Not supported