Dell E22S Switch User Manual


 
Indicator Description
Blinking Amber The indicator blinks for 15 seconds after the slot identify command.
Off The storage controller slot is operating normally.
Power indicator on
storage controller
card
Regular Blinking
Green
The storage controller card is operating normally.
Irregular Blinking
Green
The storage controller card is in a fault condition.
Off The storage controller card is not receiving power.
Removing An Integrated Storage Controller Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the server modules using the operating system commands or the CMC.
3. Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outlet
and peripherals.
4. To reduce the chassis weight, remove the following (if required):
a) hard drives
b) server modules
c) power supplies
5. If applicable, rotate the system feet inward and lay the system on its side on a flat stable surface, with the cover
release latch side on top.
6. Open the system.
7. Push down the two release levers at the edge of the card to disengage the card from the connector.
8. Orient the card so that the other end of the card disengages from the storage-controller card holder on the system
board.
86