Dell H310 Server User Manual


 
Troubleshooting 125
Smart Error Detected on a Physical Disk in a Non-Redundant Virtual
Issue: A SMART error is detected on a physical disk in a redundant virtual
disk.
Corrective Action:
Perform the following steps:
1
Back up your data.
2
Use
Replace Member
or set up a global hot spare to replace the disk
automatically.
For more information about the
Replace Member
feature, see "Using
Replace Member and Revertible Hot Spares" on page 31.
3
Replace the affected physical disk with a new physical disk of equal or
higher capacity.
4
Restore from the backup.
Replace Member Errors
NOTE: For more information about the Replace Member features, see
"Using
Replace Member and Revertible Hot Spares
" on page 31.
Source Disk Fails During Replace Member Operation
Issue: The source disk fails during the Replace Member operation.
Corrective Action: If the source data is available from other disks in the
virtual disk, the rebuild begins automatically on the target disk, using the data
from the other disks.
Target Disk Fails
Issue: The target disk fails.
Corrective Action: If the target disk fails, the Replace Member operation
aborts.
General Disk Fails
Issue: A general disk fails.