Dell M620 Computer Hardware User Manual


 
Error Code Message Information
Details The controller received a SMART error from the drive. The drive is operational but needs
replacement.
Action The drive will need replacement at the next service window.
PDR1016
Message Drive <
number
> is removed from disk drive bay <
bay
>.
LCD Message Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue persists, see Getting Help.
PDR1024
Message Drive mismatch detected for drive <
number
> in disk drive bay <
bay
>.
LCD Message Drive mismatch detected for drive <
number
> in bay <
bay
>. Install correct drive type.
Details The installed disk does not meet the array requirements, for example a SATA disk may
not operate in an array containing SAS drives.
Action Verify that the disk meets the array requirements.
PST0128
Message No memory is detected.
LCD Message No memory is detected. Inspect memory devices.
Details System BIOS was unable to detect memory in the system .
Action Re-seat the memory modules. If the issue persists, see Getting Help.
PST0129
Message Memory is detected, but is not configurable.
LCD Message Memory is detected, but is not configurable. Check memory devices.
Details System BIOS detected memory, but was unable to configure the memory for system
operation.
Action Compare system memory installation to supported system memory configurations.
PST0130
Message Memory is configured, but not usable.
LCD Message Memory is configured, but not usable. Check memory devices
Details The system BIOS encountered device failures or speed configurations that resulted in
unused memory.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
PST0131
Message System BIOS shadow failed.
LCD Message System BIOS shadow failed. Check memory devices.
Details Memory errors occurred copying BIOS image into system memory.
102