Error Code Message Information
Details The current power operational mode is non-redundant because of a power supply
exception, a power supply inventory change, or a system power inventory change.
Action Check the event log for power supply failures. Review system configuration and power
consumption.
PWR1001
Message The system performance was degraded.
LCD Message System performance degraded. Check PSUs and system configuration.
Details To avoid shutdown, system performance has been degraded.
Action Review system configuration and system logs for thermal or environmental failures and
warnings.
PWR1002
Message The system performance degraded because of thermal protection.
Details To avoid shutdown, system performance has been degraded.
Action Review system configuration and system logs for thermal or environmental failures and
warnings.
PWR1003
Message The system performance degraded because cooling capacity has changed.
Details The current power supply configuration does not meet the platform requirements to enable
redundancy. If a power supply fails the system may shutdown.
Action If unintended, review system configuration and power consumption and install power
supplies accordingly. Check power supply status for failures.
PWR1004
Message The system performance degraded because power capacity has changed.
Details The system may power down or operate in a performance degraded state.
Action Check the event log for power supply failures. Review system configuration and power
consumption and upgrade or install power supplies accordingly.
PWR1005
Message The system performance degraded because the user-defined power capacity has changed.
Details The user-defined power settings have affected system operation.
Action If unintended, review system configuration changes and power policy.
PWR1006
Message The system halted because system power exceeds capacity.
LCD Message System power demand exceeds capacity. System halted.
Details The system halted because system power exceeds capacity.
Action Review system configuration, upgrade power supplies or reduce system power
consumption.
PWR1007
Message The system performance degraded because power exceeds capacity.