Dell M620 Computer Hardware User Manual


 
Error Code Message Information
3. If the issue persists, see Getting Help.
VLT0102
Message Processor module <
name
> voltage is greater than the upper warning threshold.
LCD Message Processor module <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage condition.
If multiple voltage exceptions occur consecutively the system may power down in fail-
safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for bent pins.
3. If the issue persists, see Getting Help.
VLT0103
Message Processor module <
name
> voltage is greater than the upper critical threshold.
LCD Message Processor module <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage condition.
If multiple voltage exceptions occur consecutively the system may power down in fail-
safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for bent pins.
3. If the issue persists, see Getting Help.
VLT0104
Message Processor module <
name
> voltage is outside of the allowable range.
LCD Message Processor module <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage condition.
If multiple voltage exceptions occur consecutively the system may power down in fail-
safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for bent pins.
3. If the issue persists, see Getting Help.
VLT0200
Message The system board <
name
> voltage is less than the lower critical threshold.
LCD Message System board voltage is outside of range.
Details System hardware detected an over voltage or under voltage condition.
If multiple voltage exceptions occur consecutively the system may power down in fail-
safe mode.
Action
1. Review system logs for power supply exceptions.
122