Dell M620 Computer Hardware User Manual


 
Error Code Message Information
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
AMP0322
Message Chassis power level current is outside of range.
Details Chassis power level current is outside of the optimum range.
Action
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
ASR0000
Message The watchdog timer expired.
Details The operating system or an application failed to communicate within the time-out period.
Action Check the operating system, application, hardware, and system event log for exception
events.
ASR0001
Message The watchdog timer reset the system.
Details The operating system or an application failed to communicate within the time-out
period. The system was reset.
Action Check the operating system, application, hardware, and system event log for exception
events.
ASR0002
Message The watchdog timer powered off the system.
Details The operating system or an application failed to communicate within the time-out
period. The system was shut down.
Action Check the operating system, application, hardware, and system event log for exception
events.
ASR0003
Message The watchdog timer power cycled the system.
Details The operating system or an application failed to communicate within the time-out
period. The system was power-cycled.
Action Check the operating system, application, hardware, and system event log for exception
events.
ASR0008
Message The watchdog timer interrupt was initiated.
Details The operating system or an application failed to communicate within the time-out period. No
action was taken.
78