Dell M620 Computer Hardware User Manual


 
Error Code Message Information
SEL1510
Message An authentication error detected for Chassis Group Member <
number
>.
Details Group master CMC could not log into the group member CMC.
Action Check the login credentials of CMC.
SEL9900
Message An unsupported event occurred.
Details The current software version cannot decode this event. You may need to review this event
using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with
the -E option.
Action Upgrade the management software.
SWC4004
Message A firmware or software incompatibility detected between iDRAC in slot <
number
> and CMC.
Details FlexAddress is not implemented in one of the versions of firmware.
Action Check the firmware versions of iDRAC and CMC. Update with the latest version.
SWC4006
Message A firmware or software incompatibility detected between system BIOS in slot <
number
> and
CMC.
Details FlexAddress is not implemented in one of the versions of firmware.
Action Check the firmware versions of BIOS and CMC. Update with the latest version.
SWC4008
Message A firmware or software incompatibility detected between CMC 1 and CMC 2.
Details FlexAddress is not implemented in one of the versions of firmware. Please update the
firmware.
Action Check firmware versions. Update CMC 1 and CMC 2 firmware to match.
SWC5001
Message <
name
> upgrade failed.
Action Reboot the system and attempt the upgrade again.
TMP0100
Message The system board <
name
> temperature is less than the lower warning threshold.
LCD Message System board <
name
> temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0101
Message The system board <
name
> temperature is less than the lower critical threshold.
LCD Message System board <
name
> temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
117