Troubleshooting
69
Table 7-7. Other Errors Appearing on the BIOS
Issue Likely Causes to Check Corrective Actions
The RAID 0 goes
offline and the RAID 1
becomes degraded in a
PowerEdge R210
system with two drives.
Faulty physical disk
1
Boot system into CTLR-R and
replace faulty drive.
2
Delete the failed RAID 0 and then
create a new RAID 0. Now RAID 0
is optimal and RAID 1 is still
degraded.
3
Install OS on the RAID 0 and
backup RAID 1.
4
Delete and Recreate RAID 1 and
restore backup data.
When attempting to
update system
backplane firmware
and or Hard drive
firmware using DUPs
the updates fail.
DUPs are not
supported.
Use the DOS utilities
eSata devices appear in
Ready state in CTLR-R
Issue with the physical
connection
Remove the devices from eSata port
and plug them into the chassis.
NOTE:
eSATA devices are blocked
from virtual disk creation.
During CTRL-R,
S100/S300 do not
display greater than
eight Virtual Disks.
The function is not
supported.
Remove all physical disks except for
the last one(s) added. Then proceed
with deleting the virtual disks that
are not needed. Remember to take
account of the virtual disks that are
currently being used.
Unable to delete
Virtual Disks when
there are more than
eight Virtual Disks
present in the system.
The function is not
supported.
Remove all physical disks except for
the last one(s) added. Then proceed
with deleting the virtual disks that
are not needed. Remember to take
account of the virtual disks that are
currently being used.
Virtual disk rebuild
status while during
CTLR-R
Rebuild is not
supported in Ctrl-R.
Boot to a supported OS. Rebuild
starts. To view rebuild status, install
a supported storage application.
A5_bk0.book Page 69 Thursday, February 10, 2011 8:34 PM