Digi RCM4000 Network Card User Manual


 
User’s Manual 59
Writes the calibration constants, gain, and offset for an input based from global tables
_adcCalibS
,
_adcCalibD
, and
_adcCalibM
to designated positions in the flash memory. Depending on the flash
size, the following macros can be used to identify the starting address for these locations.
ADC_CALIB_ADDRS, address start of single-ended analog input channels
ADC_CALIB_ADDRD, address start of differential analog input channels
ADC_CALIB_ADDRM, address start of milliamp analog input channels
NOTE: This function cannot be run in RAM.
PARAMETER
channel is the analog input channel number (0 to 7) corresponding to LN0_IN to LN7_IN.
opmode is the mode of operation:
SINGLE—single-ended input line
DIFF—differential input line
mAMP—milliamp input line
int anaInEEWr(unsigned int channel, int opmode
unsigned int gaincode);
channel SINGLE DIFF mAMP
0 +AIN0 +AIN0 -AIN1
+AIN0
*
* Not accessible on Prototyping Board.
1 +AIN1 +AIN1 -AIN0* +AIN1*
2 +AIN2 +AIN2 -AIN3 +AIN2*
3 +AIN3 +AIN3 -AIN2* +AIN3
4 +AIN4 +AIN4 -AIN5 +AIN4
5 +AIN5 +AIN5 -AIN4* +AIN5
6 +AIN6 +AIN6 -AIN7* +AIN6
7 +AIN7 +AIN7 -AIN6* +AIN7*
ALLCHAN read all channels for selected opmode