Digicom 3911 Modem User Manual


 
Status Branch
4-93910-A2-GN32-40 September 1998
Table 4-2
Backup Status Screens
Active Line
1st Screen Display
Inactive Line
2nd Screen Display
Possible Inactive/Backup Line Condition
Line=Pri 4w APL
or
Line=Pri 2w APL
Bckup:2wAPL=XXXX
or
Bckup : Dial =(blank)
Good indicates that line continuity is detected.
Bad indicates that line continuity is not detected.
???? indicates that the line condition is unknown
(Backup Facility Check is making its first
determination of the line conditions since the last
retrain).
blank indicates that the Backup Line Check option is
disabled.
Line=Bkup 2w APL
or
Line = Dial Backup
Pri 4w APL =XXXX
or
Pri 2w APL =XXXX
Good indicates the line condition is good.
Bad indicates the line condition is bad.
???? indicates the line condition is unknown (Lease
Lookback has not had enough time to make an initial
appraisal of the line conditions since the last retrain).
blank indicates the Lease Loopback option is
disabled.
Line=Dial Only No second screen
display.
NOTE: When the modem is configured for Dial Only,
there is no backup.
NOTE: The leased-line interface is disabled when the
factory default options are loaded from the
Async Dial, Sync Dial, or UNIX Dial
templates.
Line=No Sync No second screen
display.
NOTE: No Sync appears when the modem is not
trained on either the primary or backup line
facility.
To exit this function and remain in the Status branch, press the key. To exit and return to the
Top-Level menu, press the
key.