D-Link DFL-500 Network Card User Manual


 
DFL-500 User Manual
11
Dimensions
8.63 x 6.13 x 1.38 in. (21.9 x 15.6 x 3.5 cm)
Weight
1.5 lb. (0.68 kg)
Power requirements
DC input voltage: 5 V
DC input current: 3 A
Environmental specifications
Operating temperature: 32 to 104 F (0 to 40 C)
Storage temperature: -13 to 158 F (-25 to 70 C)
Humidity: 5 to 95% non-condensing
Powering on
To power on the DFL-500 NPG:
Connect the AC adapter to the power connection at the back of the DFL-500 NPG.
Connect the AC adapter to a power outlet.
The DFL-500 NPG starts up. The Power and Status lights light. The Status light flashes while the
DFL-500 NPG is starting up and remains lit when the system is up and running.
DFL-500 LED indicators
LED State Description
Green The DFL-500 NPG is powered on.
Power
Off The DFL-500 NPG is powered off.
Flashing Green The DFL-500 NPG is starting up.
Green The DFL-500 NPG is running normally.
Status
Off The DFL-500 NPG is powered off.
Green The correct cable is in use, and the connected equipment has power.
Flashing Green Network activity at this interface.
Internal External (Front)
Off No link established.
Green The correct cable is in use, and the connected equipment has power.
Flashing Amber Network activity at this interface.
Internal External (Back)
Off No link established.