Diagnostic Tests
Front Panel Diagnostics
Pressing <Enter> while Central Memory Test is selected displays a
reminder to take the switch offline, if it is not offline. If the message is
displayed, take the switch offline.
If the switch passes the test, Passed is displayed:
Related error messages: DIAG-CMBISTRO, DIAG-CMBISRF,
DIAG-LCMTO, DIAG-LCMRS, DIAG-LCMEM, DIAG-LCMEMTX,
DIAG-CMNOBUF, DIAG-CMERRTYPE, DIAG-CMERRPTN,
DIAG-PORTABSENT, DIAG-BADINT, DIAG-TIMEOUT,
DIAG-INTNOTCLR
CMI Test The cmiTest verifies that control messages can be correctly sent from
any ASIC to any ASIC. It also tests that the checksum check is ok. The
switch must be offline.
Related error messages: DIAG-BADINT, DIAG-INTNIL,
DIAG-CMISA1, DIAG-CMINOCAP, DIAG-CMIINVCAP,
DIAG-CMIDATA, DIAG-CMICKSUM
SRAM Retention Test The sramRetentionTest verifies that data written into the ASIC
memories are retained and that data bits do not drop when read
after some amount of delay since the write. The switch must be
offline.
Related error messages: DIAG-REGERR, DIAG-REGERR_UNRST,
DIAG-BUS_TIMEOUT
cmemRetention Test The cmemRetentionTest verifies that data written into the SRAMs
that make up the central memory are retained and that data bits do
not drop when read after some amount of delay since the write.
The switch must be offline.
Related error messages: DIAG-LCMEM, DIAG-LCMRS,
DIAG-LCMTO
CAM Test The camTest verifies that the SID translation required by QuickLoop
and implemented using content addressable memories (cam) are
functioning correctly. The switch must be offline.
Related error messages: DIAG-CAMINIT, DIAG-CAMSID,
DIAG-XMIT
Central MemTest: passed