Enterasys Networks 8000/8600 Network Card User Manual


 
Enterasys X-Pedition 8000/8600 Getting Started Guide 17
Hardware Overview
AC Power Supply Specifications
The following table lists the specifications for the X-Pedition’s AC power supplies.
To ensure against equipment failure, you can install a redundant power supply. When two power
supplies are active in the X-Pedition, they load share, each supply delivering approximately 50
percent of the current needed. Moreover, if one of the power supplies fails, the other power supply
immediately assumes the entire load, thus preventing any system outage.
The AC power supply has a green status LED. When the LED is lit, the power supply is connected
to an appropriate power source and is active. The status LED is lit when you switch the power
supply on, not when you plug the power supply into a power source.
X-Pedition 8000 X-Pedition 8600
Dimensions 8.27 in. H x 17.25 W x 12.25 D
22.23 cm H x 43.82 W x 31.12 D
8.27 in. H x 17.23 W x 19.25 D
22.23 cm H x 43.82 W x 48.9 D
Weight Pounds: 24Lbs
Kilograms: 10.8 Kg
Pounds: 47 Lbs
Kilograms: 21.2 Kg
AC Power 100-125 VAC, 5A maximum
200-240 VAC, 3A maximum
50/60 Hz
100-125 VAC, 10A maximum
200-240 VAC, 6A maximum
50/60 Hz
Output Wattage
At 3.4 V
At 5.1 V
At 12 Volts
390 Watts
70 Amps
25 Amps
2 Amps
780 Watts
140 Amps
50 Amps
4 Amps
Operating
Temperature
Fahrenheit: 41
o
F to 104
o
F
Centigrade: 5
o
C to 40
o
C
Fahrenheit: 41
o
F to 104
o
F
Centigrade: 5
o
C to 40
o
C