Enterasys Networks 8000/8600 Network Card User Manual


 
Enterasys X-Pedition 8000/8600 Getting Started Guide 75
Installing the Hardware
SSR-POS29-04
SSR-POS21-04
9.0.0.2 Note: If your system uses a redundant power
configuration or only one power supply, you
will not be able to support more than 5 cards
in the X-Pedition 8000 and 10 in the
X-Pedition 8600.
CLI Setup
Enter the following commands at the CLI before
implementing any configurations.
1. Enable —> Configure —> <Enter>.
2. Once you reach the configuration prompt, you
can configure the SSR-POS21-04 or
SSR-POS29-04 using CLI commands as
described in the X-Pedition CLI manual. Enter
the ? character to view the options available to
you in configuration mode.
Proper Boot Sequence
Offline LED lights at power-up.
Port LEDs flicker briefly during system boot while
ports initialize.
Online LED turns on once module is active.
Common Errors
The X-Pedition is not powered up.
The module is not properly seated in the slot.
Connectors on both ends of the cable are not properly
engaged. The copper cable did not click into place or
is not properly seated.
Helpful CLI Commands for Debugging
System show hardware
System show version
System show bootlog
SSR-POS39-02
SSR-POS31-02
9.0.0.2 Note: If your system uses a redundant power
configuration or only one power supply, you
will not be able to support more than 5 cards
in the X-Pedition 8000 and 10 in the
X-Pedition 8600.
CLI Setup
Enter the following commands at the CLI before
implementing any configurations.
1. Enable —> Configure —> <Enter>.
2. Once you reach the configuration prompt, you
can configure the SSR-POS39-02 or
SSR-POS31-02 using CLI commands as
described in the X-Pedition CLI manual. Enter
the ? character to view the options available to
you in configuration mode.
Proper Boot Sequence
Offline LED lights at power-up.
Port LEDs flicker briefly during system boot while
ports initialize.
Online LED turns on once module is active.
Common Errors
The X-Pedition is not powered up.
The module is not properly seated in the slot.
Connectors on both ends of the cable are not properly
engaged. The copper cable did not click into place or
is not properly seated.
Helpful CLI Commands for Debugging
System show hardware
System show version
System show bootlog
Table 19. Line card installation notes (Continued)
Minimum
Firmware
Restrictions Special Instructions