Epson EPL-5500W All in One Printer User Manual


 
3.2.3.7 Fusing Unit Disassembly
This section describes how to remove the paper exit sensor, heater lamp, lower fusing roller, and upper fusing
roller.
Heater Lamp
Do not touch the glass surface of the lamp with your bare hands.
1. Remove the fusing guide plate. (Refer to Section 3.2.3.8.)
2. Pull the heater lamp out of the lamp holder from the front side.
When reinstalling the lamp, position its voltage indicator to the left side (non-gear end.).
Figure 3-21. Removing the Heater Lamp
EPL-5500W Service Manual Disassembly and Assembly
Rev. A 3-15