Step 9: Create a Display Lamp Hour Warning
E-mail
Global Configurator’s monitoring feature enables you to
configure an MLC 104 IP Plus controller to monitor many
parameters of the connected display devices. For example, a
monitor alert can warn the school administrator if a display
lamp hour limit is close to expiration or if a display is
inexplicably disconnected from the MLC 104 IP Plus controller.
To set a display lamp hour warning e-mail, do the following:
1. Click the Monitor tab in the Global Configurator window.
2. Click the Add Monitor button below the Monitored
Conditions dialog. The Monitored Conditions Wizard
dialog box appears.
3. Enter a name (Lamp hour) in the Enter Monitored
Condition Name field area. The label now appears in the
left pane.
4. Click the Next button. This takes you to the actions page,
where you can specify the action.
Monitored Conditions Wizard dialog
5. In the Subject Port window, select the display
(choose Epson PowerLite 7700p) for which the lamp hour
warning is to be set. A list of monitoring options appears
under the Available Options window.
6. Set the lamp hour limit by doing the following:
a. Choose Lamp Usage Time (hours): Value under the
Available Options window.
b. Enter a value (800, for example) in the Lamp Usage
Time (hours) box.
c. Click Apply Condition.
d. Click Next.
7. Click Next again to add an e-mail notification.
Display lamp hour e-mail notification
8. Click on the appropriate e-mail message and contacts, then
click Apply Email/Contacts.