Eurotech Appliances PXA255 Computer Hardware User Manual


 
VIPER Technical Manual Detailed hardware description
© 2007 Eurotech Ltd Issue E 70
PC/104 16-bit memory read/write access cycles
Unsupported PC/104 interface features
The PC/104 bus features not supported by the VIPER are as follows:
PC/104 IRQ9, IRQ14 and IRQ15 are not available under Windows CE as all
interrupt sources are fully utilized. Therefore the PC104I2 register is not available.
DMA is not supported on the VIPER’s PC/104 interface. Therefore AEN is set to a
constant logical zero.
Bus Mastering is not supported on the VIPER’s PC/104 interface. Therefore do not
connect another VIPER or any other master add-on board to the VIPER PC/104
interface.
Shared interrupts are not supported on the VIPER’s PC/104 interface. Therefore do
not connect more than one add-on board to the same interrupt signal line.
BALE is set to a constant logical one as the address is valid over the entire bus
cycle.
The PXA255 PCMCIA memory controller does not support 8-bit memory read
accesses for common memory space.
AEN
BALE
SBHE
A<0:23>
MEMCS16
IOCHRDY
(S)MEMR/(S)MEMW
DATA (read)
DATA
(
write
)
VALID
VALID
VALID VALID
VALID
VALID