Eurotech Appliances PXA270 Computer Hardware User Manual


 
ZEUS Technical Manual Connectors, LEDs and jumpers
© 2007 Eurotech Ltd Issue D 95
JP5 & JP6 – CAN bus termination
Connector: 2-way, 2.54mm (0.1") through-hole header
JP5 JP6
Pin Signal name Pin Signal name
1 CANH 1 Centre tap
2 Centre Tap 2 CANL
JP5 & JP6 Description
62
Ω Termination connected
62
Ω Termination disconnected
(default)
Only insert jumpers JP5 and JP6 if the ZEUS is at the end of the network.
JP7 - JTAG Enable
Connector: 2-way, 2.54mm (0.1") through-hole header
Pin Signal name
1 VCC (+5V)
2 VCC_JTAG
This jumper is used to enable debug of PXA270 using JTAG interface.
JP7 Description
JTAG Enable
Normal Operation (Default)
Only insert jumper JP7 for JTAG access to PXA270.
JP6
JP5
12
2
1
1
2