Extron electronic 1212 Switch User Manual


 
3-21CrossPoint 300 Matrix Switchers • Operation
Example 6: Saving a preset
The following steps show an example in which the current configuration is saved
as a preset in a CrossPoint 300 1616. The steps show the front panel indications
that result from your actions.
1. Press and release the Esc button (figure 3-33).
ENTER PRESET VIEW ESC
CONTROL
P
ress the Esc button to clear all selections.
The LED
blinks once
.
Figure 3-33 — Clear all selections
2. Press and hold the Preset button for approximately 2 seconds until the Preset
LED blinks (figure 3-34).
PRESET
1234
P
ress and hold the Preset button until
t
he Preset LED blinks.
If you then save the configuration to a lit preset number,
the configuration data at that preset location will be overwritten
.
Lit
(Preset Assigned)
Unlit
(Preset Unassigned
)
Preset 17 Preset 18 Preset 2
0
Preset 19
All input and output LEDs with
assigned presets light.
Figure 3-34 — Enter Save Preset mode
3. Press and release the Output 1 button (figure 3-35).
ENTER PRESET VIEW
CONTROL
1 2 3 4
The Enter LED blinks to indicate
the need to save the preset.
The Preset LED continues to blin
k.
P
ress and release the Output 1 button.
T
he LED blinks to indicate that this preset
n
umber is selected but not saved.
Preset 17 Preset 18 Preset 20Preset 19
Figure 3-35 — Select the preset