Extron electronic 1212 Switch User Manual


 
Operation, cont’d
CrossPoint 300 Matrix Switchers • Operation3-36
Performing a system reset from the front panel
The front panel reset is identical to the rear panel system reset (see “Performing a
system reset from the rear panel” on page 3-39) and to the
Esc
ZXXX SIS
command (see chapter 4, “Programmer’s Guide”). A system reset:
Clears all ties and presets
Clears all video and audio mutes
HVA switchers — Sets all input audio levels to unity gain (+0 dB)
Reset the switcher to the factory default settings by pressing and holding the
RGBHV button and Audio button while you apply AC power to the switcher
(figure 3-58).
System reset does not replace user-installed firmware upgrades.
RGBHV AUDIO
I/O
1
2
P
ress and hold the RGBHV and Audio
b
uttons while you apply power to the switcher.
The switcher’s LEDs blink and then go dark.
Continue to hold the RGBHV and Audio buttons until all
input and output LEDs return to the unlit state and the
RGBHV and Audio LEDs turn on.
Release the RGBHV and Audio buttons.
Pow
er
Figure 3-58 — System reset