Extron electronic 3200s Switch User Manual


 
4-9Matrix 3200/6400 Series • Programmer’s Guide
QUICK RECALL OF
GLOBAL PRESETS COMMANDS ASCII (HOST-SWITCHER) RESPONSE (SWITCHER-HOST)
Quick Recall Preset
. Rpr
Notes:
1. If the Quick Recall Preset (
.) command is issued without an active write, then error E10 occurs.
2. Complete backplane switch within 60mSeconds (apprx.) after receipt of the command.
3. Recall must take place 100mSeconds after End Write Mode command (
p ).
4. Quick recall command only recalls last entered direct write preset.
SET NAMES COMMANDS ASCII (HOST-SWITCHER) RESPONSE (SWITCHER-HOST)
Read Global preset name NG
Write Global preset name nG , NamP
Read Room preset name NP *
Write Room preset name nP * , NamP
Read Room Name NR
Write Room Name nR , NamR
Read Virtual Input Name NI
Write Virtual Input Name nI , NamI
Read Virtual Output Name NO
Write Virtual Output Name nO , NamO
ADVANCED INSTRUCTION SET AND SIMPLE INSTRUCTION SET COMMANDS (PAGE 3 OF 3)
ZAP CONFIGURATION COMMANDS ASCII (HOST-SWITCHER) RESPONSE (SWITCHER-HOST)
Zap All Global presets & names
zG ZapG
Zap individual Global zT ZapT
Zap All Room presets & names zP ZapP
Zap individual Room Preset zT * ZapT
Zap All RGB Delay to Ø sec. zD ZapD
Zap all Audio Gains to Ø dB. zA ZapA
UnMute RGB/Audio (All Mutes) zZ ZapZ
Master Reset zXXX ZapXXX
ERROR CODES
If the switcher receives a command that is invalid or contains invalid parameters, it will return an Error Code
response. The error code response has the format “Exx”. Following is a list of possible error code responses.
Description of Error code
E
Ø
1 Invalid input channel number (too large)
E
Ø
5 Device is off
E1
Ø
Invalid command
E11 Invalid preset number (too large)
E12
Invalid output number (too large)
E13
Value too large (Gain)
E14
Command not available for matrix configuration
E2
Ø
Invalid BME number
E21
Invalid Room number
E22
Busy
E23