Extron electronic MPS 409 Switch User Manual


 
Command
ASCII Command
(host to switcher)
Response
(switcher to host)
Description
Switcher-
initiated
messages
Status command of Mic DIP switches
Read status of DIP switch positions 41S
X1*
X1(] X1*
= 48V phantom power
(0=off, 1=on)
X1(
= Mic/Line input
(0=Mic, 1=Line)
Front panel security lockout (executive mode)
Lock front panel access 2X/x
Exe 2
]
Locks volume, mic, input
selection.
X
Lock front panel mic controls 1X/x
Exe 1
]
Locks mic controls.
X
Unlock front panel access 0X/x
Exe 0
]
Unlocks front panel.
X
View Lock Status X/x
X#]
Lock status is (0=off, 1=on)
System reset (to factory defaults)
Reset switcher to factory defaults
E
ZXXX
}
Zpx
]
Resets the system to the
following factory defaults:
Mode
X&
= 1
Input
X1!
= 1
Main Volume
X1)
= 70
Mic Volume
X$
= 0
Executive Mode
X#
= 0
Mic threshold
X*
= 8
Follow Sub Mode
X#
= 0
Mic Power
X#
= 0
Ducking Level
X1@
= 6
Request information
View current selection status I/i
Mod
X&
1G
X@
2G
X@
3G
X@
4G
X@
=
X!
G
X@]
Displays selected input in each
group and input routed to the
program audio output.
X&
1 = Single Switcher mode,
2 = Separate Switcher mode
X!
= Group 1 through 4
(1 = VGA, 2 = DVI,
3 = HDMI, 4 = Composite).
X@
= Inputs 0 through 2 (0-3
for HDMI) for each group
(input 0 = off).
Firmware Update/Upload
Upload firmware
E
Upload
}
Upl
]
Query Firmware version
Query firmware version Q/q
X1)] X1)
= firmware version number
to the second decimal.
Setup/Naming commands
Set the unit name
E
X1(
CN
}
Ipn
X1(]
Return the unit name to default
E
CN
}
Ipn
MPS-409
]
View unit name
E
CN
}
Ipn
X1(]
Request part number
Request part number N/n
60-xxxx-xx
]
Displays the MPS 409 part number
MPS 409 • SIS Programming and Control 25