FieldServer FS-8700-41 Computer Drive User Manual


 
FS-8700-41 Simplex 4100 Driver Manual Page 56 of 58
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com
Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldserver.com
A61
MICROPHONE PRETONE MSG# ANALOG 144-61-0
A62
PHONE OFFHOOK TIMER TIMER 144-62-0
A63
PHONE CALLBACK TIMER TIMER 144-63-0
A64
PHONE TIMEOUT TIMER TIMER 144-64-0
A65
REMOTE MASTER PHONE TIMEOUT TIMER TIMER 144-65-0
A66
SPEAKER SWITCH OFF AUTO COUNT ANALOG 144-66-0
A67
AUDIO RESET PULSE TIMER TIMER 144-67-0
A68
VTG 1 PRIORITY ANALOG 144-68-0
A69
VTG 2 PRIORITY ANALOG 144-69-0
A70
CHANNEL 1 ROUTING PRIORITY ANALOG 144-70-0
A71
CHANNEL 2 ROUTING PRIORITY ANALOG 144-71-0
A72
CHANNEL 3 ROUTING PRIORITY ANALOG 144-72-0
A73
LOCAL SPEAKER ROUTING PRIORITY ANALOG 144-73-0
A74
AUDIO SUPERVISION PULSE TIMER VTG1 TIMER 144-74-0
A75
AUDIO SUPERVISION PULSE TIMER VTG2 TIMER 144-75-0
A76
ENABLE/DISABLE STATISTIC GROUP ANALOG 144-76-0
A77
ENABLE/DISABLE STATISTIC OUTPUT PORT ANALOG 144-77-0
A78
5 SEC TIMER FOR REMOTE MASTER PHONES TIMER 144-78-0
A79
CLEAR PEAK PULSE ANALOG 144-79-0
A80
PRECODE MESSAGE NUMBER - VTG 1 ANALOG 144-80-0
A81
AFTER CODE MESSAGE NUMBER - VTG 1 ANALOG 144-81-0
A82
PRECODE MESSAGE NUMBER - VTG 2 ANALOG 144-82-0
A83
AFTER CODE MESSAGE NUMBER - VTG 2 ANALOG 144-83-0
A84 '
QUIET' MESSAGE NUMBER ANALOG 144-84-0
A85
2 SECOND TIMER - VTG 1 TIMER 144-85-0
A86
2 SECOND TIMER - VTG 2 TIMER 144-86-0
A87
MIKE INHIBIT TIMER TIMER 144-87-0
A88
MIKE INHIBIT TIMER SETPOINT ANALOG 144-88-0
A89
PHONE CALLBACK TIMER SETPOINT ANALOG 144-89-0
A90
PHONE TIMEOUT TIMER SETPOINT ANALOG 144-90-0
A91
VTG & AMPLIFIER TROUBLE DISABLE TIMER TIMER 144-91-0
A92
SUPERVISION NOT ACTIVE - TBL DELAY TIMER TIMER 144-92-0
A93
4 WIRE DETECTOR RESET EXTEND TIMER TIMER 144-93-0
A94
ACTIVE MESSAGE NUMBER - VTG 1 ANALOG 144-94-0
A95
ACTIVE MESSAGE NUMBER - VTG 2 ANALOG 144-95-0
A96
ACTUAL CHIPSET PLUGGED INTO VTG 1 ANALOG 144-96-0
A97
ACTUAL CHIPSET PLUGGED INTO VTG 2 ANALOG 144-97-0
A98
BATTERY TROUBLE COUNTER COUNTER
144-98-0
A99
AC POWER FAIL COUNTER COUNTER
144-99-0
A100
SYSTEM TYPE ANALOG 144-100-0
A101
FIRST STAGE TIMER ANALOG 144-101-0
A102
FIRST STAGE TIMER SETPOINT ANALOG 144-102-0
A103
MASTER MIKE 5 SECOND UNKEY DELAY ANALOG 144-103-0
A104
REMOTE MIKE 1 5 SECOND UNKEY DELAY ANALOG 144-104-0
A105
REMOTE MIKE 2 5 SECOND UNKEY DELAY ANALOG 144-105-0
A106
MASTER MIKE'S PRETONE TIMER ANALOG 144-106-0
A107
MASTER MIKE'S PRETONE SETPOINT ANALOG 144-107-0