Fisher MPX-CD163 Network Card User Manual


 
ALARM SET SETTINGS
ALARM SET settings
Example: To use both an external alarm and
the motion sensor to detect alarms
Press the MENU button.
The MAIN MENU screen will be displayed.
Use the cursor button to select
ALARM SET” and then press the
NEXT button.
The ALARM SET screen will be displayed.
Use the cursor button to select
ALARM OFF”, use the setting
buttons to select “ON”, and then
press the NEXT button.
The ALARM OPERATION SET screen will
be displayed.
Use the cursor buttons to select
ALARM EXT. OR M.SENSOR”, and
then press the setting buttons to
select the “EXT. AND M. SENSOR”.
Display examples:
The following four alarm detection methods are available.
EXT. OR M.SENSOR:
An alarm is generated when either an external alarm or a
motion sensor alarm is detected.
EXT. AND M.SENSOR:
An alarm is generated when both an external alarm and a
motion sensor alarm is detected.
MENU
1
(MAIN MENU)
1 LANGUAGE ¤
2 CLOCK SET ¤
3 DISPLAY SET ¤
4 VCR SET ¤
5 ALARM SET ¤
6 SECURITY SET ¤
7 CONTROL SET ¤
8 ALARM DATA ¤
(*:NEXT)
NEXT
2
(ALARM SET)
ALARM ON *
ACTIVE REC. OFF
MOTION SENSOR OFF
VIDEO LOSS OFF
(*:NEXT)
3
NEXT
+
+
4
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
DURATION 10 S
RETRIGGER OFF
ALARM LIST ON
BUZZER ON
ALARM DISPLAY ¤
EXT.:
An alarm is only generated when an external alarm is
detected.
M.SENSOR:
An alarm is only generated when a motion sensor alarm is
detected.
Use the cursor button to select
DURATION “10S”, and then press
the setting buttons to select “5”.
An alarm display time of 5 seconds has
been set.
Display examples:
CC: An alarm is generated only while the alarm is actually
being detected. (Minimum duration 1 second)
NC: An alarm is generated until the alarm detection is reset.
INDIV.: This lets you set the alarm duration separately for
each camera.
Use the cursor button to select
RETRIGGER OFF”, and then press
the setting buttons to select “ON”.
Display examples:
OFF: Simultaneous alarms are not detected.
ON: Simultaneous alarms are detected.
ALARM SET-1
+
5
1, 2, 3, 4, 5, 10, 20 ...
(in 10-second
intervals), 180S, CC,
NC, INDIV.
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
DURATION 10 S
RETRIGGER OFF
ALARM LIST ON
BUZZER ON
ALARM DISPLAY ¤
+
6
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
DURATION 10 S
RETRIGGER OFF
ALARM LIST ON
BUZZER ON
ALARM DISPLAY ¤
ALARM SET-1
English
61