Configuring a Custom Cable
The Configure Custom Cable function allows you to define custom test standards
for up to four custom cables. You can change the following parameters for your
custom configuration:
Baseline standard for cable definition
NVP (Nominal Velocity of Propagation)
Maximum cable length
Fault threshold for impedance anomalies
Active pair assignments for cable pairs
Resistance
Characteristic impedance test enabled or disabled
Attenuation test enabled or disabled
NEXT and NEXT@REMOTE tests enabled or disabled
RL test enabled or disabled
ACR and ACR@REMOTE tests enabled or disabled
PSNEXT and PSNEXT@REMOTE tests enabled or disabled (Model
DSP-2000)
Note
To determine the NVP for a custom cable configuration refer to the
previous section, “NVP Calibration.”
During the configuration process, you can abandon the changes you have made by
pressing ! Abort. To reset a parameter back to the default value, highlight
the parameter; then press @ Set to Default. To reset all of the
parameters back to default values, highlight the test standard on Page 1 of 6 of the
configuration screens; then press @ Set to Default.