Fluke DSP-100 Network Card User Manual


 
Tests Run per Test Standard During an Autotest
C
C-5
Table C-1. Tests Run per Test Standard During an Autotest (continued)
Test Standard
1
Attenuation ACR Return Loss
Prop.
Delay
2
Delay
Skew
2
Coax Cables
IEEE 10BaseT 5-10 MHz
100BaseTX 16 MHz 1-80 MHz
100BaseT4 2-12.5 MHz ■■
IEEE 802.12 4-UTP 1-15 MHz ■■
IEEE 802.12 STP 1-100 MHz 1-100 MHz
TokenRing, 4 Mb/s 4 MHz 1-12 MHz
TokenRing,16 Mb/s, Passive 16 MHz 1-25 MHz
TokenRing,16 Mb/s, Active 16 MHz 1-25 MHz
TP-PMD 16 MHz 1-80 MHz
Twin-Ax: RJ45 pins 4, 5, S
ARCnet
Aus/NZ Class C Channel 1-16 MHz
Aus/NZ Class D Channel 1-100 MHz 1-100 MHz
Aus/NZ Class C Basic Link 1-16 MHz
Aus/NZ Class D Basic Link 1-100 MHz 1-100 MHz
All Tests 1-100 MHz 1-100 MHz 1-100 MHz ❒❒
1.
2.
Test standards version 4.0.
Resistance, propagation delay, and delay skew are always measured; results appear on printed test
reports.
Pass/Fail result given.
Pass/Warning result given.
Results within the accuracy specifications of the test tool are marked with an asterisk.
NEXT test is run but not displayed. Results are used to calculate ACR.