Fluke DSP-100 Network Card User Manual


 
DSP-100/2000
Users Manual
3-18
Pressing @ View Plot produces the RL plot screen. Figure 3-6 shows an
example of the screen and Table 3-9 describes the items on the screen.
5
2
1
6
4
3
gc13c.eps
Figure 3-6. The RL Plot Screen
Table 3-9. Items on the RL Plot Screen
Item Description
1
The cable pair relevant to the plot.
2
Frequency range in MHz of the RL test.
3
Margin is the difference between the limit and measured values plotted at the cursor’s
position. Use L R to move the cursor left or right. If you move the cursor beyond the highest
test frequency specified by the selected test standard, the readout shows the RL value at
the cursor’s position.
4
The limits for RL, as defined by the selected test standard.
5
Decibels of RL for the cable pair.
6
The measured RL for the cable pair.
RL@REMOTE (Model DSP-2000)
The RL@REMOTE test is identical to the RL test, except that the RL values are
measured from the remote end of the cable.