Chapter 12 CPU Module Replacement 12-9
Caution – After installing the CPU module, you must reconnect the power cable to
the power supply.
9. Log in to the XSCF again, using an account with platadm or fieldeng
privileges.
10. Perform an initial diagnosis of the newly installed CPU module.
The following example shows a test after adding PSB#01 to a SPARC Enterprise
M5000 server:
11. Confirm that the installed CPU module is recognized by the server and that the
error indicator asterisk (*) is not displayed.
12. Confirm that no error has occurred.
13. Change the key position on the operator panel from Service to Locked.
14. Power on the existing domains.
15. Set the following for the added CPU module:
■ Set up XSB for the added CPU module.
■ Set up the domain.
XSCF> testsb 01
XSCF> testsb 01
Initial diagnosis is about to start. Continue? [y|n] : y
Initial diagnosis is executing.
Initial diagnosis has completed.
XSB Test Fault
---- ------- --------
01 Passed Normal
XSCF> showhardconf -M
XSCF> showlogs error -v
XSCF> showstatus
XSCF> poweron -a