Fujitsu M4000 Server User Manual


 
Chapter 4 FRU Replacement Preparation 4-11
2. Type the showhardconf -u command to display the number of FRUs in each
unit.
Refer to the showhardconf -u man page for more information.
3. Verify the state of the status LEDs on the FRU.
Refer to
TABLE 2-11 for LED status.
CODE EXAMPLE 4-5 showhardconf -u
XSCF> showhardconf -u
SPARC Enterprise M5000; Memory_Size:64 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B | 1 |
| CPUM | 4 |
| Freq:2.530 GHz; | ( 8) |
| MEMB | 8 |
| MEM | 64 |
| Type:1A; Size:1 GB; | ( 64) |
| DDC_A | 4 |
| DDC_B | 2 |
| IOU | 2 |
| DDC_A | 2 |
| DDCR | 2 |
| DDC_B | 2 |
| XSCFU | 1 |
| OPNL | 1 |
| PSU | 4 |
| FANBP_C | 1 |
| FAN_A | 4 |
+-----------------------------------+------------+