Command Specifications
3 -
96
C141-E167
This parameter page specifies transfer of the “Page code” list of the parameter page supported by
the IDD in the SEND DIAGNOSTIC command and the RECEIVE DIAGNOSTIC RESULTS
command to the INIT. Figure 3.19 shows the format of this parameter page. The page code list
supported by the IDD is transferred to the INIT by the RECEIVE DIAGNOSTIC RESULTS
command which is issued following the SEND DIAGNOSTIC command that specifies this
parameter page (shown in Section 3.4.2 (1) )
Bit
Byte
76543210
0 X ‘00’ (Page Code)
100000000
2 X ‘00’ (Page parameter length)
3 X ‘00’ (Page parameter length)
Figure 3.19 SEND DIAGNOSTIC parameters: page code list
b. Logical/physical address conversion
This parameter page specifies conversion of the address information expressed in either the
“Logical Block Address,” “Physical Sector Address” or “Byte Distance from the Index” format
to another expression format. Figure 3.20 shows this parameter page format. The INIT can
specify the address information that should be converted in this parameter page of the SEND
DIAGNOSTIC command, and can read the conversion results by the RECEIVE DIAGNOSTIC
RESULTS command (see Section 3.4.2 (2)).
Bit
Byte
76543210
0 X ‘40’ (Page Code)
100000000
2 X ‘00’ (Page Parameter Length)
3 X ‘0A’ (Page Parameter Length)
400000
Address Format Before Conversion
5 0 0 0 0 0 Address Format After Conversion
6
7
Logical or Physical Address
13
Figure 3.20 SEND DIAGNOSTIC parameters: logical/physical address conversion
~
~
~
~
~
~