Command Specifications
3 - 18 C141-E167
* Set at shipping time
The IDD ignores this specification and operates with the settings
specified at shipping.
f) ACE (AIP checking enabled)
This specifies whether or not it is permitted to check AIP (Asynchronous Information
Protection).
"1" (Permitted): Permitting check
"0"*(Prohibited): Prohibiting check
* Set at shipping time
The IDD ignores this specification and operates with the settings
specified at shipping.
g) AGD (AIP generation disabled)
This specifies whether or not it is permitted to generate AIP (Asynchronous Information
Protection).
"1" * (Prohibited):Prohibited generation
"0" (Permitted): Permitted generation
* Set at shipping time
The IDD ignores this specification and operates with the settings
specified at shipping.
h) RTD (reselection timeout delay)
This specifies the reselection timeout delay time.
Bit 1 Bit 0 Reselection Time-out Delay
0 0 250 [ms]*
0 1 3 [ms]
10Reserved
11Reserved
* Set at shipping time
i) Spindle motor start delay time
This specifies the time after power on until the motor starts.
The IDD's motor starts after [(value specified in this parameter) x (IDD's SCSI ID x 0.1)] seconds from
the power is switched on. If X '00' is specified in this parameter, the motor starts immediately after the
power is switched on, no matter what SCSI ID is set in the IDD. Also, the IDD starts the motor
immediately no matter what value is specified in this parameter.
This parameter is enabled only when set in the "Auto Motor Start Mode" with a setting terminal.