Fujitsu MAP3147 Computer Drive User Manual


 
1.5 UNIT ATTENTION Condition
C141-E167 1 - 21
Power on [=29-01]
Reset [=29-02]
TARGET RESET [=29-03]
Transciever Mode Changed to SINGLE-ENDED [=29-05]
Transciever Mode Changed to LVD [=29-06]
Mode parameters changed [=2A-01]
Reservations Preempted [=2A-03]
Reservations Released [=2A-04]
Registrations Preempted [=2A-05]
Commands cleared by another INIT [=2F-00]
Spindle synchronized [=5C-01]
Spindle not synchronized [=5C-02]
Microcode has been changed [=3F-01]
Changed Operating Definition [=3F-02]
Device Identifier Changed [=3F-05]
However, if the IDD responds with a BUSY status or QUEUE FULL status due to its not being able to
receive the command that was issued, the UNIT ATTENTION condition is not cleared.
The above CHECK CONDITION status response that is the cause of the UNIT ATTENTION
condition hold can be prohibited by the specification of the CHANGE DEFINITION command.
When the CHECK CONDITION status response is prohibited, the IDD executes the commands it
receives normally, except in the case of a RESERVATION CONFLICT status, BUSY status or
QUEUE FULL status. In this case, the UNIT ATTENTION condition for the INIT that issued that
command is cleared.
See Section 3.1.4 “CHANGE DEFINITION” concerning setting details.
(2) INQUIRY command
The INQUIRY command is executed normally, but the UNIT ATTENTION condition is not cleared.
(3) REQUEST SENSE command
One of the following operations is performed depending on whether or not the IDD is in the sense
data hold state (shown in Section 1.6).
a. In the case of a Sense Data Hold state
The IDD executes the REQUEST SENSE command normally and sends the sense data which are
being held to the INIT. In this case, the UNIT ATTENTION condition is not cleared.
b. In the case of a State other than a Sense Data Hold state