Fujitsu T5440 Server User Manual


 
24 SPARC Enterprise T5440 Server Administration Guide July 2009
5. To check the status of the RAID rebuild, type:
For example:
This example indicated that RAID volume c0t1d0 is resynchronizing. If you issue
the command again once synchronization is complete and the disk is back online,
the RAID status changes from RESYNCING to OK.
Related Information
“Hot-Plug a Nonmirrored Disk” on page 24
“Delete a Hardware RAID Volume” on page 21
Hot-Plug a Nonmirrored Disk
1. Verify which hard drive corresponds with which logical device name and
physical device name.
See “Disk Slot Numbers” on page 20.
Caution To avoid data corruption or loss, ensure that no applications or processes
are accessing the hard drive.
# raidctl
# raidctl
RAID Volume RAID RAID RAID
Volume Type Status Disk Status
-----------------------------------------------------------------
c0t1d0 IM RESYNCING c0t1d0 OK
c0t2d0 OK