Fujitsu T5440 Server User Manual


 
42 SPARC Enterprise T5440 Server Administration Guide July 2009
Note The question in TABLE: Expected Behavior of Halting or Rebooting the
Control (primary) Domain on page 42 regarding whether domaining is enabled
pertains only to the UltraSPARC T1 processors. Otherwise, domaining is always
enabled.
TABLE: Expected Behavior of Halting or Rebooting the Control (primary) Domain
Command
Domaining
Enabled?
Other Domain
Configured? Behavior
halt Disabled N/A For UltraSPARC T1 Processors:
Drops to the ok prompt.
Enabled No For UltraSPARC T1 Processors:
See message in 02.
For UltraSPARC T2 Processors:
Host powered off and stays off until powered
on at the SC.
Enabled Yes Soft resets and boots up if the variable
auto-boot?=true. Soft resets and halts at
ok prompt if the variable auto-boot?=
false.
reboot Disabled N/A For UltraSPARC T1 Processors:
Powers off and powers on the host.
Enabled No For UltraSPARC T1 Processors:
Powers off and powers on the host.
For UltraSPARC T2 Processors:
Reboots the host, no power off.
Enabled Yes For UltraSPARC T1 Processors:
Powers off and powers on the host.
For UltraSPARC T2 Processors:
Reboots the host, no power off.
shutdown -i 5 Disabled N/A For UltraSPARC T1 Processors:
Powers off the host.
Enabled No Host powered off, stays off until powered on
at the SC.
Enabled Yes Soft resets and reboots.